Power control cable, Dc power cable, Figure 6-2 – NEC NEAX 2000 IPS User Manual

Page 67: Power cable connection (internal battery option), Table 6-2

Advertising
background image

Chapter 6 Cabling

Internal Cabling

NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1

Page 57

Power Control
Cable

The power control cable provides a connection between the MP and the AC/DC
power supply for controlling battery backup function and MJ/MN alarm indication.

Note:

One power control cable is contained in the PIM or Base. It is not necessary
to order a separate power control cable except for spare or replacement.

DC Power Cable

The DC power cable provides a connection between the AC/DC power supply for
extending the 27 VDC input in a multiple-PIM configuration, when battery backup
option is required.

An Internal Battery is installed in every PIM.

Figure 6-2 Power Cable Connection (Internal Battery Option)

Table 6-2 Power Control Cable

NAME CODE

PART

NUMBER

REMARKS

PWR CNT CA-D

151031

Power Control Cable
• For PIM 1 - PIM 7
• BWB - PZ-PW121/122

(Included in PIM)

PWR CNT CA-E

151032

Power Control Cable
• For PIM 0
• BWB - PZ-PW121/122

(Included in Base and PIM for Dual System)