User level 9, In forming the user 9, Self-help 9 – Nortec 132-3091 User Manual

Page 17: Sys tem mes sages 9, Re mote in di ca tion 9, Dou ble unit op er a tion 9, How to install the replacement cylinder, Extended shutdown

Advertising
background image

6.

Remove snap-fit red cap from coil assembly and

slide coil off the actuator.

7.

Loosen actuator with wrench and unscrew from

plastic valve body.

8.

Clean the exposed core and spring and plastic

drain valve port.

9.

Important: Tapered end of spring must be

installed toward the solenoid. Reassemble,

tighten actuator 1/4-turn past hand-tight.

10.

Clean out the end of the hose, then reconnect it to

the drain valve body with the clamp.

11.

Fit mounting screws through drain valve body, one

through ring terminal on green ground wire.

12.

WARNING: To prevent the possibility of electrical

shock the green ground wire must be reinstalled

before power is restored.

13.

Push the two slip-on terminals back onto the two

tabs on the coil. The terminals, although not

identical, are reversible.

HOW TO INSTALL THE REPLACEMENT

CYLINDER

1.

Reverse procedure should be followed to install

new cylinder. Main disconnect is to be left open

until cylinder is completely installed and

reconnected.

2.

Ensure that cylinder is secured properly by the

re-usable tie wrap and mounting brackets within

the unit.

3.

The cylinder plug wires are color-coded in

accordance with colored dots beside the electrode

pins on top of the cylinder.

4.

This color-coding must be adhered to when

replacing cylinder plugs on pins.

5.

With cylinders having six primary voltage cylinder

plugs, it should be noted that there are two of each

color.

6.

Care must be taken so that cylinder leads of the

same color are always directly opposite each other

as indicated by the dot formation on the top of the

cylinder.

7.

The white cylinder plug on all units is for the

sensor electrode which always goes on the single

pin surrounded by a plastic shoulder.

8.

Ensure that cylinder plugs fit snugly on the pins.

9.

If cylinder plugs become loose, it is best to obtain

a new replacement plug. Consult factory.

EXTENDED SHUTDOWN

Before disconnecting power to the humidifier for a

period of extended shutdown, ALWAYS DRAIN the

cylinder first. Otherwise, the electrodes are subject to

harmful corrosion which drastically shortens cylinder

life. Do NOT leave the switch in the DRAIN position

indefinitely as the drain coil could burn out. Leave the

switch in the OFF position and “open” the main

external fused disconnect to stop power to the

humidifier. Close the shut off valve in the water supply

line feeding the humidifier. Lock the cabinet door(s) to

prevent unauthorized tampering. All doors are factory

supplied with keyed locks. DO NOT LEAVE KEY IN

LOCK. ACCESS SHOULD BE LIMITED TO

AUTHORIZED PERSONNEL ONLY.

As long as the NHMC is powered, it will

automatically drain the cylinder when there has not

been a call for humidity for an extended period of time.

The cylinder will remain empty until there is a call for

humidity at which time the fill valve will open and refill

the cylinder. The unit will go through its normal

stabilization process for optimum operation.

- 14 -

0.50

10 ga Wire

Cylinder plug

Hex (Allen)
5/64 (2mm)

Cylinder Plug Installation Instruction

for Part # 135-4012 (R,Y or B)

12/08/94

Cylinder Plug

Cylinder Plug Installation Instruction

For Part # 135-4012 (R, Y, or B)

0.50"

10 GA Wire

Hex (Allen)

5/64" (2 mm)

Figure #16

Cylinder Plug Installation

Oil Here

Figure #17

Where To Oil

Advertising