5 applications and techniques – Nilfisk-Advance America IVB 7-M User Manual

Page 10

Advertising
background image

08

english

IVB 3-M
IVB 5-M
IVB 7-M

1)

Option depending on model

5 Applications and techniques

5.1 Techniques

If used correctly, additional ac-
cessories, suction nozzles and
suction hoses can enhance the
cleaning action and reduce the
cleaning effort.

Effective cleaning is achieved if
you follow just a few guidelines
in combination with your own
practical experience in special
fields.
Here are some basic tips.

5.1.1 Picking up dry

substances

The suction hose diameter must
suit the position of the switch in
order to pick up dry, nonflam-
mable dust with maximum room
concentration values.
There must always be a safety
filter bag in the tank before dry
substances with maximum room
concentration values are picked
up. See section 9.5 “Accesso-
ries” for ordering number.

To pick up harmless dust we
recommend the use of a waste
bag. See section 9.5 “Accesso-
ries” for ordering number. Dis-

posal of the picked up material
is then simple and hygienic.

After picking up liquids, the filter
element is wet. A damp filter el-
ement clogs more quickly when
dry substances are picked up.
For this reason the filter element
should be washed and dried or
replaced by a dry element be-
fore dry substances are picked
up.

Always use a filter bag/waste
bag that is suitable for the type
of dust (see table):

IVB 3-M

Type of dust

Filter bag/waste bag

Handling/waste disposal

• Nonhazardous

dust

Waste bag
No. 302001310

1. Thorough cleaning - see section 4.5.
2. Waste disposal - see section 7.2.1

Dust with MAC
values

≥ 0.1 mg/m³

• wood

dust

Filter bag
No. 302000565

Waste disposal - see section 7.2.2

IVB 5-M / 7-M

Type of dust

Filter bag/waste bag

Handling/waste disposal

• N

onhazardous dust

Dust with MAC
values

≥ 0.1 mg/m³

Observe any ad-
ditional national
regulations

Waste bag
IVB 5-M: No. 302001311
IVB 7-M: No. 302001480

Waste disposal:
1. Remove hose with tool sleeve from
tool
2. Thorough cleaning - see section 4.6
3. Waste disposal - see section 7.2.1

Dust with MAC
values

≥ 0.1 mg/m³

• wood

dust

Filter bag
IVB 5-M: No. 302001138
IVB 7-M: No. 302001909

Waste disposal - see section 7.2.2

Do not pick up flammable
substances.

Advertising
This manual is related to the following products: