Napco Security Technologies GEM-DXRP1 User Manual

Page 15

Advertising
background image

15

K E Y P AD F U N C T I O N S

The keypad can provide access to a wide assortment of utility functions. The functions are displayed in a prompting “YES/NO” format.

1 To enter the Function Menu, press

A

.

In all UL-listed or high-security installations, a valid User Code must first be entered followed by

A

.

2 To skip a function, answer NO (

F

) or

A

.

3 To select and execute a function, answer YES (

E

) or

J

.

Functions may be manually scrolled forward or backward using

A

and

B

, respectively.

To return to normal keypad operation, press the

C

button. The keypad will automatically return to its normal operating

mode if no activity is detected for longer than one minute.

Display Zone Faults?

Displays the zone number of zones that are not secured. Press

the NEXT and PRIOR Buttons (as displayed on-screen) to scroll faulted zones (required for
GEM-P3200/9600 panels. GEM-P816/1632/1664 panels will auto-scroll).

Display Zones Bypassed?

Displays bypassed zones. Press NEXT(

E

) and

PRIOR (

F

) to scroll bypassed zones (required for GEM-P3200/9600 panels. GEM-

P816/1632/1664 panels will auto-scroll).

Display Zone Directory?

Displays a listing of all zones in the Area. Press NEXT

(

E

) and PRIOR (

F

) to scroll zone directory (required for GEM-P3200/9600 pan-

els. GEM-P816/1632/1664 panels will auto-scroll).

(Note: This function available with GEM-

P1632 control panel firmware version 9a or later).

D I S P L A Y
Z N F A U L T S Y / N

D I S P L A Y
Z N B Y P A S S E D Y / N

D I S P L A Y
Z N D I R E C T O R Y Y / N

Advertising