Maintenance


Pump Oil Change

1.) Place a suitable container below the pump to catch the used oil.

a. VRX

Remove the bolts that connect the pump to the engine. Remove fill cap and rotate pump
upside down.

b. BXD

Remove drain plug.

2.) Allow the used oil to drain completely.

a. VRX
Rotate pump to the upright position, and reinstall mounting bolts.
b. BXD

Reinstall drain plug.

3.) Please dispose of used oil in a manner that is compatible with the environment. We suggest you

take used oil in a sealed container to your local recycling center or service station for reclamation.
Do not throw it in the trash, pour it on the ground or down the drain.

4.) With the pump in a level position add oil to the pump, (see capacities below). Use Universal

Tractor Transmission Oil (part #COCP2101) or Mobil1 15W50 synthetic oil.

a. VRX

Add specified capacity

b. BXD

Fill to middle of sight glass


1577541

Comet VRX Pump

1577542

Comet BXD Pump

Oil Capacity: 4.3 oz. (0.13L)

Oil Capacity: 3.4 oz. (0.10L)

Fill Cap

Fill Cap

Oil Sight Glass

Drain Plug

Bolts