Troubleshooting

Problem

Engine will not start

SOLUTION: A

Low/Surging pressure or no water flow

SOLUTION: B,C,D,E,F,G

No chemical injection

SOLUTION: H,I,J,K

Cause Solution

A- Engine starting instructions not followed

See engine manual for starting instructions

B- Insufficient water supply

See water supply section of this manual

C- Plugged pump inlet filter

See maintenance section of this manual

D- Wrong nozzle

Make sure high pressure nozzle is being used

E- Plugged nozzle

Remove nozzle, check for blockage

F- Worn nozzle

Replace nozzle

G- Leak in pressure hose

Replace pressure hose

H- Wrong nozzle

Make sure chemical nozzle is being used

I- Back pressure from extra long pressure hose

Use standard length hose

J- Leak in chemical siphon hose

Replace hose – use hose clamps if necessary

K- Chemical strainer not submerged

Make sure strainer is completely submerged

Specifications



1577541

1577542

PSI (bar)

2600 (179)

PSI (bar)

2700 (186)

GPM (l/min)

2.5 (9.4)

GPM (l/min)

2.5 (9.4)

Max Water Temp

140

°F (60°C)

Max

Water

Temp

140

°F (60°C)

Noise Level

75 dB

Noise Level

82 dB

Dimensions
L x W x H

30.5 x 24 x 24.3

Dimensions
L x W x H

30.5 x 24 x 24.3

Weight 77

lbs

Weight 83