CHAPTER 7 8-BIT TIMERS 50, 60, AND 61

User’s Manual U15331EJ4V1UD

157

Figure 7-28. Operation Timing in PWM Output Mode

(When Both Edges Are Selected) (When CR50 Is Overwritten)

Count clock

CR50

TCE50

INTTM50

TO50

2N + 1

TM50

2N

00H

00H

00H

01H

FFH

FFH

01H

2N + 1

01H

02H

FEH

2N

Overflow

Overflow

Overflow

Count start

CR50 overwrite

Remark N = 00H to FFH