Appendix A

Specifications

© National Instruments Corporation

A-7

NI 7831R User Manual

by the digital outputs use the
following equation:

Where j is the number of digital outputs being used to source current.

Power available at I/O connectors ......... +4.50 to +5.25 VDC at 1 A total,

250 mA per I/O connector pin

Physical

Dimensions (not including connectors)

NI PXI-7831R................................. 16 cm by 10 cm (6.3 in. by 3.9 in.)

NI PCI-7831R ................................. 17 cm by 11 cm (6.7 in. by 4.3 in.)

I/O connectors ........................................ Three 68-pin female high-density

VHDCI type

Maximum Working Voltage

Maximum working voltage refers to the signal voltage plus the
common-mode voltage.

Channel-to-earth

..................................... ±12 V, Installation Category I

Channel-to-channel

................................ ±24 V, Installation Category I

Environmental

The NI 7831R is intended for indoor use only.

Operating Environment

Using 40 MHz timebase......................... 0 to 55

°C, tested in accordance

with IEC-60068-2-1 and
IEC-60068-2-2

Using 80 MHz timebase......................... 0 to 55

°C in all NI PXI chassis

except the following:
0 to 40 °C when installed in an
NI PXI-1000/B or NI PXI-101X

current sourced on channel i

i

1

=

j

Advertising