RUNNING SENSOR CABLE IN NEW CONSTRUCTION

Scheduling and Preparation
Plan to schedule the sensor wiring after the electrical wiring is finished. That way you can avoid cable
routes which could potentially induce interference over the sensor cable. The basic rules are:
• Never run the sensor cable through the same hole as an electrical cable.
• Never run the sensor cable into the same J-box as electrical cable.
• Avoid running the sensor cable beside the electrical cable. Keep it at least 3 or 4 feet distant
from any electrical power cable.