TROUBLESHOOTING

SYMPTOMS

CAUSES

REMEDIES

The water pump will not start

The motor thermic protection is open

Check the mains voltage (+/- 5%

tolerance). Check the phases

in the plug are connected well.

The water pump will not enter

The no-return valve does not seal

Replace the valve or the gasket

in bypass

and check the pressure valve

body wear.

Leakage from the water system

Eliminate the leaks

of the gun

The water pump does not reach

Nozzle worn

Replace the nozzle

maximum pressure

Pressure ball or adjustment housing

Replace the faulty part

worn or spring broken

Pressure valve gaskets worn

Replace the valve gaskets

Pistons seal gasket worn

Replace the gaskets

Nozzle holding head in position

Turn the head on high pressure

low pressure

Strong vibrations on the water pump

Water supply insufficient

Check the water supply flow and

the relative pressure (2÷10)

Check the water filter and clean

it if necessary

Prime the pump without the lance

Alien matter under a check valve

Check the valves, clean and reassemble

The burner will not start

Diesel filter blocked

Clean the filter

Diesel nozzle blocked

Clean the filter

Worn or broken electrodes

Replace the electrodes

The pressure switch remains open

Replace the pressure switch

Safety thermostat is open

Replace the safety thermostat

Anormal noise of Diesel pump

Low diesel

Fill diesel tank or work on cold water

No detergent suction

High viscosity of the employed

Further dilute the detergent

detergent

Detergent filter blocked

Clean the filter