OPERATING INSTRUCTIONS

STARTING THE PRESSURE WASHER

BEFORE STARTING THE PRESSURE WASHER
1. Read all safety instructions throughout this manual.

2. Be sure the motor switch is in the “OFF” position, red button pushed.

3. Ensure outlet is the proper voltage (120 volts).

4. Insert the male power plug into a grounded AC outlet.

5. Press and release the “RESET” button on the GFCI power cord.

6. Press “RESET” each time after plugging the GFCI power cord into a power source.

COLD WATER OPERATION

1. After following all preparation instructions, turn the water supply on.

2. Turn the unit on by pushing the pump switch on the control panel. Once the unit starts, squeeze

the trigger gun “ON” for 2 minutes to purge all air and mineral deposits from the system. This

operation is to be done without lance terminal end.

3. Turn the pump switch to OFF position, release the trigger gun and lock in the “OFF” position.

Fit the lance terminal end. To ensure you are in the high pressure mode, turn the nozzle holder

to the right.

4. Your

R

ANGER

157394 is now ready to be used as a cold water pressure washer. Turn the

unit on by pushing the pump switch on the control panel. Squeeze the trigger-gun to spray a high

pressure stream and release the trigger to stop the stream.

5. Adjust pressure with the unloader valve to the desired pressure.

!

Do not allow the unit to operate in bypass mode (with trigger

released in the “OFF” position) for more than 3 minutes.

Premature failure of pump packing may occur if left in bypass

mode for longer than 3 minutes.

Never look directly into the nozzle unless it is disconnected from the

spray wand.

20 amp outlet