4 default configuration – Network Technologies RACKMUX-T15 User Manual

Page 12

Advertising
background image

NTI RACKMUX RACKMOUNT ANSI TERMINAL DRAWER

8

2.1.4 Default Configuration

The terminal is delivered pre-configured with the following settings suitable for most RS232 serial console connections at 9600
baud using VT-100 emulation.


Disp SETUP Menu

Columns = Econ-80
Cursor = Blink Block
Screen Saver = Off
Lines = 24
Background = Dark
Page Length = 1 x Lines
Auto Page = Off
Width change clear = Off
ANSI Reverse = Off
Display= LCD

F2 General SETUP Menu

Personality = VT 100
Enhance = On
Status Line = Standard
Scroll Speed = Jump
Auto Scroll = On
End of Line Wrap = On
Rcvd CR = CR
Monitor = Off
Attribute = Char

F3 Keybd SETUP Menu

Keyclick = Off
Key Repeat = 5
Xmt Limit = None
Margin Bell = Off
Language = US
Keycode = ASCII
NRC = Off
Bell Volume = 2
NUM Start = Off
DEL Keypad = Dot/Del

F4 Comm SETUP Menu

Baud rate = 9600
Data / Stop Bits = 8/1
Parity = None
Rcv Hndshake = Xon/Xoff
Xmt Hndshake = Xon/Xoff
Comm Mode = FDX
XPC Handshake = On
Printer Selection = Off
Multiple Sessions = Off
Ethernet Mode = Off
Auto Connect = Off

F5 Misc SETUP Menu

Wprt Intensity = Dim
Wprt Reverse = Off
Wprt Underline = Off
Block End = US/CR
Ptr Baud rate = 38400
Ptr Data/Stop Bits = 8/1
Ptr Parity = None
Ptr Rcv Hndshake = Xon/Xoff
Ptr Xmt Hndshake = Xon/Xoff
Ptr Rcv = Off

F9 Lan Setup Menu

Local IP Address = {blank}
Netmask = {blank}
Gateway = {blank}
Remote IP 0..B Address ={blank}
Port 0...B = 23
Term Type = vt100
Ethernet Node ID = (default}



For use with an Ethernet connection the following parameters need to be configured:

Display Setup (F1 in setup mode)

Page Length = 1*Lines (only required if ‘Multiple Sessions=On’)

Communications Setup (F4 in setup menu)

Multiple Sessions = Off

or O

n

Ethernet Mode = On
Auto Connect = Off

or

On

‘Multiple Sessions=On’ should be set if multiple telnet sessions are required.
‘Auto Connect=On’ is used to prevent the need to press return to establish a telnet connection.

LAN Setup (F9 in setup mode)

Local IP Address =

IP address of the terminal

Netmask =

Netmask value for the network

Gateway =

gateway address if required by the network

Remote IP 0 Address =

IP address of first server

Port = 23

Remote IP 1 Address =

IP address of second server

Port = 23

….
Remote IP B Address =

IP address of twelfth server

Port = 23

Term Type =

Same as personality specified in General Setup menu

Ethernet Node ID =

leave at default value

Note: If only one host is being connected to, all twelve Remote IP addresses and ports should be set to the same value.

Note: Eight separate telnet sessions are allowed if any columns other than Econ-80 is selected in Terminal Display Set-
up. If Econ-80 is selected, the Multiple Sessions option allows twelve concurrent telnet sessions to be used.