Troubleshooting, Problem possible causes possible remedies – North Star 8000 PPG User Manual

Page 10

Advertising
background image

9

TROUBLESHOOTING

Problem

Possible Causes

Possible Remedies

Engine will not start.

a) Low oil level.
b) Fouled spark plug.
c) Out of fuel.
d) Stop switch in OFF position.

a) Fill crankcase to proper oil level.
b) Clean or replace spark plug.
c) Fill fuel tank.
d) Place switch in ON position.

Voltage too low.

a) Engine speed too slow.

b) Generator is overloaded.

a) Bring generator to a qualified
technician for adjustment.
b) Reduce the load. (See Load
Application section of this manual.)

Circuit breaker trips.

a) Defective load connected to generator.
b) Defective receptacle.
c) Generator overloaded.

a) Disconnect load.
b) Replace receptacle.
c) Reduce the load. (See Load
Application section of this manual.)

Voltage too high.

a) Engine speed too high.

a) Bring generator to a qualified
technician for adjustment.

Generator overheating.

a) Generator is overloaded.

b) Insufficient ventilation.

a) Reduce the load. (See Load
Application section of this manual.)
b) Make sure there is at least 3 feet of
clearance on all sides of generator.

No output voltage.

a) Defective load connected to generator.
b) Broken or loose wire.

c) Defective receptacle.
d) Defective stator.

e) Defective rotor.

f) Defective capacitor.

a) Disconnect load.
b) Bring generator to a qualified
technician for repair.
c) Replace receptacle.
d) Bring generator to a qualified
technician for repair.
e) Bring generator to a qualified
technician for repair.
f) Bring generator to a qualified
technician for repair.

Engine lacks power.

a) Generator is overloaded.

b) Dirty air filter.

a) Reduce the load. (See Load
Application section of this manual.)
b) Clean or replace air filter.

Engine shuts down
during operation.

a) Out of fuel.
b) Low oil level.

a) Fill fuel tank.
b) Fill crankcase to proper oil level.