Smallest installed footprint – Raypak MVB 504 thru 2004 User Manual

Page 4

Advertising
background image

Smallest Installed Footprint

The MVB’s compact design allows for easy installation in the most challenging equip-
ment rooms. It’s easy to handle and install, but still user friendly to service. The MVB has
the smallest installed footprint of any vertical boiler, only 5.4 square feet. The MVB con-
tains all of it’s components to the inside of the cabinet, so there won’t be any fans or
valves hanging off the cabinet that need extra clearance. The compact design fits
through a 30” door opening making it the perfect choice for those hard to reach retrofit
projects.

Model

Venting

Category

Boilers

Water Heaters

Input

Min.

Input

Output

Efficiency

Input

Output

Efficiency

503

IV

500

435

87%

500

435

87%

125

753

IV

750

653

87%

750

653

87%

188

1003

IV

999

869

87%

999

869

87%

250

1253

IV

1250

1088

87%

1250

1088

87%

312

1503

IV

1500

1305

87%

1500

1305

87%

375

1753

IV

1750

1523

87%

1750

1523

87%

438

2003

IV

1999

1739

87%

1999

1739

87%

500

504

I*

500

420

84%

500

420

84%

357ª

754

I*

750

630

84%

750

630

84%

536ª

1104

I*

1100

924

84%

1045

888

85%

786ª

1504

I*

1500

1260

84%

1425

1211

85%

1071ª

2004

I*

1999

1679

84%

1900

1615

85%

1428ª

MBTUH

Models

Dimensions (inches)

Operating

Weight

(lbs.)

Amps‡

MVB

Cat. I*

MVB

Cat. IV

B

Ht.

D

E

F

G

NPT

H

NPT

K-Ø

Cat. I*

K-Ø

Cat. IV

M

Cat I*

M

Cat IV

N

CA Ø

P

R

V

504

503

43

32

35

23-3/4

1

2

8

6

14-1/8 14-1/2

6

35

6

2

600

12

754

753

49

38

41

29-3/4

1

2

10

6

16

14-1/2

6

41

6

2

660

12

1104

1003

55

44

47

35-3/4

1-1/4

2-1/2

10

6

16

14-1/2

6

47

6

2

720

12

1504

1253

61

50

53

41-3/4

1-1/4

2-1/2

12

8

18-1/8 17-3/4

8

53

6

2

780

12

1503

67

56

59

47-3/4

1-1/4

2-1/2

8

17-3/4

8

59

6

2

840

12

2004

1753

75

62

65

53-3/4

2

2-1/2

14

8

20-1/8 17-3/4

8

68

9

5

940

18

2003

81

68

71

59-3/4

2

2-1/2

8

17-3/4

8

74

9

5

1000

18

PHY

SICAL D

A

TA

*Category I with vertical vent, category III with horizontal venting and no extractor.

†Category IV requires sealed vent with condensate drain. Category I uses conventional B vent.
ªBoilers only.
Note: Ratings are for natural or propane gas and for elevations up to 5,000 ft. above sea level. For higher elevations, consult the factory.

*Category I with vertical vent, category III with horizontal venting and no extractor.

†NPT is for Natural Gas. For Propane, NPT= 1” for all water heater/boiler sizes.

‡Current draw is for heater only. (Supply breaker must have a delayed trip.)

4

Advertising
This manual is related to the following products: