Raypak MVB 504 thru 2004 User Manual

Page 8

Advertising
background image

MVB

HEA

T EXCHANGER

JACKET

OTHER

GAS TRAIN

SAFETIES

OPERA

TING CONTROLS

ASME, National Board Registered, 160 PSI

• HLW Stamp

ⅷ

N/A

• H Stamp

N/A

ⅷ

Heat Exchanger Tubes

• Copper

ⅷ

ⅷ

• Cupro Nickel

⅜

⅜

Bronze Headers

ⅷ

⅜

Cast Iron Headers

N/A

ⅷ

Pressure Relief Valve

• 60 PSI

⅜

ⅷ

• 125 PSI

ⅷ

⅜

• 30, 45, 75, 150 PSI

⅜

⅜

Temperature & Pressure Gauge

ⅷ

ⅷ

Pump

• 120V, Single-Phase

⅜

⅜

Indoor/Outdoor Certified

ⅷ

ⅷ

Vent Terminal

• Outdoor

⅜

⅜

• Through-the-Wall

⅜

⅜

Fully-Enclosed Controls

ⅷ

ⅷ

Combustible Floor Rated

ⅷ

ⅷ

120V Power Supply with 120V/24V Transformer

ⅷ

ⅷ

On/Off Switch

ⅷ

ⅷ

Programmable Pump Time Delay, Single-Phase

• Included in TempTracker Mod Controller

ⅷ

ⅷ

Terminal Block Connections

• Enable / Disable

ⅷ

ⅷ

• External Interlocks

ⅷ

ⅷ

• 0-10 VDC Setpoint/Direct Drive Input (cat. I)

ⅷ

ⅷ

12 Diagnostic Lights with 256-Event History

ⅷ

ⅷ

Status Display Lights (4)

ⅷ

ⅷ

Temperature Controller with 3 Water Sensors

• TempTracker Mod (up to 4:1 Turndown, cat. IV)

ⅷ

ⅷ

• Outdoor Reset Sensor

N/A

⅜

Multiple Boiler Controller

• TempTracker Mod+, up to 16 boilers

⅜

⅜

• Y-200, up to 40 boilers (LonWorks optional)

⅜

⅜

Hot Surface Ignition System

• 1-try (standard on cat. IV)

⅜

⅜

• 3-try (standard on cat. I)

ⅷ

ⅷ

High/Low Gas Pressure Switches

⅜

⅜

Blocked Vent and Air Pressure Switches

ⅷ

ⅷ

High Limit Switch

• Manual Reset, Fixed

ⅷ

ⅷ

• Manual Reset, Adjustable

⅜

⅜

• Automatic Reset, Adjustable

⅜

⅜

Low Water Cut-Off, 24V

• With Manual Reset and Test Buttons

⅜

⅜

Flow Switch

ⅷ

ⅷ

Modulating Combination Gas Valve

ⅷ

ⅷ

Combustion Air Blower

ⅷ

ⅷ

TruSeal Direct-Vent Ready

ⅷ

ⅷ

Additional Safety Valve

• Motorized (externally mounted)

⅜

⅜

• Solenoid (externally mounted)

⅜

⅜

CSA-Certified Efficiency

• Cat. IV - 87% at Full Fire

ⅷ

ⅷ

• Cat. I - 84% to 85% (see MBTUH table)

ⅷ

ⅷ

Air Filter

⅜

⅜

Alarm System

⅜

⅜

CSD-1 / GE GAP Control System

⅜

⅜

Low NOx

• Meets all current requirements

ⅷ

ⅷ

Cold Water Start

• Prevents internal condensation on start-up

⅜

⅜

Cold Water Run

• Prevents condensation in continuous low-temp operation

⅜

⅜

Water Heaters

(Type WH)

Boilers

(Type H)

ⅷ

ⅷ

= Standard

⅜

⅜

= Optional

Raypak, Inc. • 2151 Eastman Avenue, Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-8725 • www.raypak.com

Cat. No. 3400.11E Effective 07-01-08 Replaces 11-1-07