MAINTENANCE

REPLACING AND CLEANING AIR FILTER

See Figures 29 - 30.
For proper performance and long life, keep air filter clean.

Remove the air filter cover by pushing down on the latch

with your thumb while gently pulling on the cover.

Remove the air filter and clean it in warm soapy water.

Rinse and let dry completely.

Reinstall the air filter.

Replace the air filter cover by inserting the tabs on the

bottom of the cover into the slots on the air filter base;
push the cover up until it latches securely in place.

NOTE: For best performance, replace annually.

FUEL CAP

WARNING:

A leaking fuel cap is a fire hazard and must be replaced
immediately.

The fuel cap contains a non-serviceable filter and a check
valve. A clogged fuel filter will cause poor engine perfor-
mance. If performance improves when the fuel cap is loos-
ened, check valve may be faulty or filter clogged. Replace
fuel cap if required.

SPARK PLUG REPLACEMENT

This engine uses a Champion RCJ-6Y or NGK BPMR7A
spark plug with .025 in. electrode gap. Use an exact re-
placement and replace annually.

STORING THE PRODUCT

Clean all foreign material from the product. Store idle unit

indoors in a dry, well-ventilated area that is inaccessible
to children. Keep away from corrosive agents such as
garden chemicals and de-icing salts.

Abide by all ISO and local regulations for the safe storage

and handling of gasoline.

When storing 1 month or longer:

Drain all fuel from tank into a container approved for

gasoline. Run engine until it stops.