Er and – Roberts Gorden Infrared Heater BH-150 User Manual

Page 12

Advertising
background image

BH-S

ERIES

I

NSTALLATION

, O

PERATION

AND

S

ERVICE

M

ANUAL

6 of 59

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.

2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream
from where the burner and burner tube connect.

FIGURE 3: Standard Reflector

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

BH-40

6

27

52

27

16

69

133

69

BH-60

6

35

62

35

16

89

158

89

BH-80

6

38

65

38

16

97

166

97

BH-100

6

40

70

40

16

102

178

102

BH-115/125

6

46

76

46

16

117

194

117

BH-140/150

6

50

79

50

16

127

201

127

BH-175/200

8

52

82

52

21

133

209

133

FIGURE 4: One Side Reflector

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

BH-40

6

9

52

44

16

23

133

112

BH-60

6

9

62

47

16

23

158

120

BH-80

6

9

69

54

16

23

176

138

BH-100

6

9

76

59

16

23

194

150

BH-115/125

6

9

82

65

16

23

209

166

BH-140/150

6

9

85

69

16

23

216

176

BH-175/200

8

9

88

73

21

23

224

186

C

B

D

A

FIGURE 5: Two Side Reflectors

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

BH-40

6

15

52

15

16

39

133

39

BH-60

6

23

65

23

16

59

166

59

BH-80

6

25

71

25

16

64

181

64

BH-100

6

27

77

27

16

69

196

69

BH-115/125

6

32

83

32

16

82

211

82

BH-140/150

6

35

87

35

16

89

221

89

BH-175/200

8

40

91

40

21

102

232

102

C

B

D

A

Advertising