Ricoh 70E User Manual

Page 55

Advertising
background image

Preparation for Installation 4-7

II

L

00

1) Unplug the Power Supply Cable prior to connecting.

2) Be careful not to have other personnel plug in the power cable while

performing the connecting.

3) Be sure to use power supply cable which complies with the following

specification :

Power plug rating ; Min. AC 250V, Min. 15A (2-Pole, 3-Wire, Grounded)

6-15P UL Listed, CSA Certified in North America

Type CA, Conformed to IEC 950 in Europe

Power cable rating ; Min. AC 250V, Min. 15A

Type SJT or SVT, UL Listed, CSA Certified in North
America

Conformed to IEC 950 in Europe

4) Use the Power Supply Cable which is approximately 50 mm longer for

the FG. The cable should be designed as below, so the FG power cable
remains connected if the other cables are accidentally disconnected.

5) Make sure that the power cables are connected to the correct terminals

(“L”, “N” ) on the power plug and Terminal Block. ( FG power cable is
connected to chassis.)

6) The socket-outlet shall be installed near the printer and be easily

accessible.

Approx. 50mm

L

interna

N

FG

Power Cable

WARNING

Advertising