Installing ASM-10/8

1

Quick Start Guide

Installation of ASM-10/8 should be carried out only by an experienced
technician. If you are familiar with ASM-10/8, use this quick start guide to
set it up for operation.
Perform the following steps for both the local and the remote units:

QS .1 Installing ASM-10/8

Switch and
Jumper Settings

Set the ASM-10/8 internal jumpers and switches correctly for the chosen
operating mode. Refer to the table below for the possible settings.

Warning

Make sure that the power cord is disconnected before removing the

unit's cover.

Jumper

Possible Settings

Default Setting

SWITCH

EN
DIS

EN

2W/4W

4W
2W

4W

AGC

ON
CTRL

ON

CARRIER

ON
CTRL

ON

XMT LEVEL

0 dbm
-3 dbm
-6 dbm
-9 dbm

0 dbm

XMT IMPD

600
300
150
LOW

150