(8) Connecting 144-pin 0.5-mm-pitch Foot Pattern

Figure 3.18 shows how to connect the emulation probe to the 144-pin 0.5-mm-pitch foot pattern on
the target system with the M3T-FLX-144NSD (separately available), and here following is its
procedure.

(1) Attach the NQPACK144SD included with the M3T-FLX-144NSD to the target system.

For details on how to attach the M3T-FLX-144NSD to the target system, see the instruction
manual of the M3T-FLX-144NSD.

(2) Attach the YQPACK144SD included with the M3T-FLX-144NSD to the NQPACK144SD.
(3) Insert the YQ-GUIDE's included with the YQPACK144SD to the YQPACK144SD.
(4) Attach the M30830T-EPB to the M3T-FLX-144SD.
(5) Attach the M3T-FLX-144NSD to the YQPACK144SD.

Figure 3.18 Connecting the emulation probe and 144-pin 0.5-mm-pitch foot pattern

CAUTION

Notes on Connecting the Target System:

• Take care not to attach the converter board in a wrong direction. It may cause a fatal

damage to the emulator.

• The small connectors of the M3T-FLX-144NSD are guaranteed for only 50

insertion/removal iterations.

Advertising