6.2 When the Emulator Debugger Does Not Start Up Properly

(1) When the LED Display of the PC7501 is Abnormal

Table 6.1 LED's abnormal display and its checkpoints

Error

Connection to

the target system

Checkpoint

LEDs do not light up.

All LEDs remain lit.

The POWER LED of
"STATUS OF TARGET"
does not light up.

The CLOCK LED of
"STATUS OF TARGET"
does not light up.

The RESET LED of
"STATUS OF TARGET"
does not go out.

-

-

Connected

Not connected

Connected

Connected

Recheck the power cable is connected to the
PC7501.

See the user's manual of the PC7501.

Recheck the connection between the PC7501 and
this product.

See "3.5 Connecting the PC7501" (page 33).

Check power is properly supplied to the target
system and that the target system is properly
grounded.

(1) Check that both the main and sub clocks of the

emulator debugger are not set to "EXT".

See the CLK command of the emulator
debugger.

(2) Check the oscillation circuit in the emulator is

oscillating.

See "3.2 Selecting Clock Supply" (page 25).

(1) Check the oscillation circuit in the target system

is oscillating.

(2) Check the switches in the emulation probe are

correctly set.

See "3.3 Setting Switches" (page 29).

Check the reset pin of the target system is pulled
up.