128

Settings

When you have a MIDI sequencer connected, set this
parameter to Local Off. Most conventional sequencers have
the Thru function set to On, so as seen in the figure, when
information describing what has been played on the keyboard
(1) arrives at the sound generator via two separate routes (2),
notes could be sounded twice or sometimes get cut off. To
prevent this, the setting called “Local Off” is used to disconnect
the route in (1).

Local On:

The keyboard and the internal sound generator are
in a linked state.

Local Off:

The keyboard and the internal sound generator are
in an unlinked state. No sound will be produced by
the keyboard when it is played.

When a Roland MT series instrument is connected, it
is not necessary to make the Local Off setting. The
MT transmits a Local Off message when the power is
turned on. If you turn on the power in the order of
the VIMA

MT series, Local Off will be set

automatically.

Disconnecting the Internal Sound
Generator and Keyboard
(Local Control)

(1)

MIDI

MIDI

MIDI

MIDI

(2)

IN

IN

OUT

OUT

Sequencer

Memory

Sound

Generator

Each note played is sounded twice

Soft Thru On

Local On

Local On

Sound is emitted

Sound Generator

Local Off

No sound produced

Sound Generator

Setting

Explanation

On

The Local Control is set to On.
The keyboard and internal sound generator are
connected.

Off

The Local Control is set to Off.
The keyboard and internal sound generator are
disconnected. Playing the keyboard will not
produce sound.

RK-500-e.book 128 ページ 2006年8月11日 金曜日 午後4時29分