Installation, Valve description, Installation of the dc sparker – Regency C33-LP3 User Manual

Page 11

Advertising
background image

Regency

®

CLASSIC C33-3 Freestanding Gas Stove

11

VALVE

DESCRIPTION

1) Gas

on/off

knob

2) Manual

high/low

adjustment

3) Pilot

Adjustment

4) Thermocouple

Connection

5) Main

Operator

6) Outlet Pressure Tap
7) Inlet

Pressure

Tap

8) Pilot

Outlet

9) Main Gas Outlet
10) Flange Securing Screw Holes
11) Alternative TC Connection Point
12) Thermoelectric Unit
13) Additional Valve Mounting Hole

INSTALLATION OF THE

DC SPARKER

1) Attach the ground wire to the grounding

stub.

After

Before

4) Loop the wires

through the heat

shield.

5) Install the plastic bushing over the outside of

the hole to protect the wires from the sharp

edges.

6a) Attach the ground wire to the DC spark

mounting bracket.

6b) Next, attach the DC sparker generator wires

to the DC sparker.

ground wire

DC spark generating wires

Piezo ignition wires

2) Loop the 2 DC Spark generating wires as

well as the ground wire through the hole

provided.

With Bottom Shield:

With Pedestal:

Select the hole to be used (depending

on which side you prefer to install the DC

Sparker box).

8) Attach the heat shield to the DC Sparker,

then mount onto either the Pedestal or the

Bottom Shield, using the velcro already
attached to the DC Sparker mounting

bracket.

Note: We recommend attaching the DC

sparker box to the bottom rear of the unit

(away from the heat source). Ensure this

a convenient location, easily accessible for

battery replacement.

3) Attach the Piezo

Ignition wire to

the DC Sparker

box.

INSTALLATION

7) Install the supplied battery into the DC Sparker

Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box

will need to be replaced annually.

Battery

Compartment

(APPLIES ONLY TO LP UNITS)

Advertising
This manual is related to the following products: