8) If optional fan is installed, remove thermodisc

to bracket by removing three (3) phillips head
M5 screws.

9) Remove front cover with Piezo Igniter by

removing two (2) sheet metal screws.

10) Loosen four (4) phillips head M5 valve

mounting screws from underside of fi rebox.
Push valve assembly forward on the teardrop
slots and drop down. Diagram 3.

Diagram 1

Diagram 2

4) Disconnect gas line to stove.

5) Disconnect 3/8" NPT pipe from 90

o

elbow

on valve.

6) Disconnect the two (2) switch wires from

valve.

7) Remove two (2) orifi ce bracket screws inside

fi rebox.

Diagram 3

REMOVING

VALVE ASSEMBLY

1) Shut off gas supply.

2) If optional fan is installed, disconnect power

source to stove.

3) Remove access panel.

a) Front panel on pedestal model. See

diagram 1.

b) Panel from bottom of leg shield. See

diagram 2.

Note: Access panel only has to be loos-

ened to be taken out.

11) Disconnect Piezo wire.

To remove valve from valve assembly,

continue.

12) Remove two (2) thermopile wires.

13) Remove thermocouple with a 9 mm (metric)

wrench.

14) Remove pilot nut with an 11 mm wrench.

15) Remove valve to orifi ce nut with a 13/16"

wrench.

16) Remove inlet pipe with pipe wrench. Note

orientation of 90

o

elbow.

17) Remove two (2) phillips head M5 screws

on each side of the valve.

18) Remove valve and remove gas out 90

o

brass

fi tting. Note orientation of fi tting.

INSTALLING

VALVE ASSEMBLY

1) To install a new valve assembly, reverse

instructions for removing valve. See as-
sembly steps 1-11.

2) Check for leaks and manifold pressure. See

Gas Pressure Test instructions.

3) To reinstall valve, reverse instructions for

removing valve assembly, steps 12-18.