Maintenance, Glass replacement, Log replacement – Regency C33-LP3 User Manual

Page 19: Gold-plated doors

Advertising
background image

Regency

®

CLASSIC C33-3 Freestanding Gas Stove

19

7) Install the replacement glass. When placing

the replacement glass in the door, make
sure that the glass gasketing will properly
seal your unit.

8) Put glass in place and then position glass

retainer rod.

Note: Do not use substitute materials. If

your glass does break, do not con-
tinue to use your unit until it has been
replaced.

9) Position the glass retainer clips and door

securing bracket. Secure the glass retaining
screws but do not overtighten as this may
cause the glass to break after the unit heats
up.

10) Tighten all screws evenly.

Note: Do not overtighten as this may cause

breakage.

11) Slip door over hinge pins.

12) Put hinge caps back onto door.

13) Close door and secure the security bracket

with the screw.

GLASS

REPLACEMENT

Your CLASSIC stove is supplied with high
temperature, 5 mm Neoceram ceramic glass
that will withstand the highest heat that your
unit will produce. In the event that you break
your glass by impact, purchase your replace-
ment glass from an authorized Regency

®

dealer

only, and follow our step-by-step instructions
for replacement.

1) Allow the stove to cool before removing or

replacing glass.

2) To remove the door from the stove remove

the securing screw located between the ash-
lip and the door, then unfasten the latch.

3) Remove gold hinge caps from door.

4) Lift door off hinge.

5) Lay door on a soft, fl at surface.

6) Remove the screws in the glass retainer

clips and remove the glass retainer rod.
Remove any remaining pieces of glass
and ensure that the door is free of debris.
Use caution when removing broken glass
to avoid injury.

MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken
logs. Turn off the gas valve and allow the unit
to cool before opening door to carefully remove
the logs. The pilot light generates enough heat
to burn someone.

If for any reason a log should need replace-
ment, use only Regency

®

replacement logs.

The position of these logs must be as shown
in the diagram under Log Installation.

NOTE: Improper positioning of logs may

create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.

GOLD-PLATED DOORS

The 24 carat gold plated fi nish on the door
requires little maintenance, and need only
be cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as
they may harm the fi nish and void the warranty.
Clean any fi ngerprints off before turning
the unit on.

Advertising