TROUBLESHOOTING

PROBLEM

CAUSE

REMEDY

Motor won’t start

Lower tube hasn’t been telescoped
out to its full length

No power (power failure)

Connection lead wire defect

Motor or switch defect

Pull the lower tube out to its full
length.

Check circuit breaker.
Check fuse

Check circuit breaker.
Replace lead or have lead checked
(electrician); never use defective lead.
Contact the authorized service center.

Material is not sucked in properly (re-
duced vacuuming power)

Machine is clogged or blocked

Vacuum bag too full

Speed setting too low

Clean tool

Empty bag

Adjust to higher speed

IF THESE SOLUTIONS DO NOT SOLVE THE PROBLEM, CONTACT YOUR AUTHORIZED SERVICING DEALER.