System setting list – Roland SD-50 User Manual

Page 73

Advertising
background image

73

System Settings

System Setting List

Indication

Range

Explanation

LCD Contrast

1–10

Adjusts the brightness of the display.
Higher settings make the display brighter.

GM TYPE

CLASSICAL,
CONTEMPORARY

Switches the GM sound type.

Classical
The basic sound set that blends well with an ensemble.
You can also choose this if GM2 data compatibility is important.

Contemporary
A sound set that emphasizes the realism of each instrument. This setting is selected
when the power is turned on.

Master Tune

415.3–466.2 Hz

Adjusts the tuning of the entire SD-50. The displayed value is the frequency of the A4
key (middle A).

Output Gain

-12– +12 dB

Adjusts the SD-50’s output gain so that the output level will be suitable when recording
to an external device.

Minus One

PART 1–PART16,
4&5, 1&4&5,
EXCEPT 10,
EXCEPT 2&10

This specifies the part(s) that will be muted when you use the Player function to play
back SMF data (p. 69).

Battery

ALKALINE, Ni-MH

Selects the type of battery that’s being used.
ALKALINE: Alkaline batteries
Ni-MH: Nickel-metal hydride batteries

Mastering

OFF,
SHARP,
CLEAR, POWER

This effect is provided for use on the output of the sound generator; it makes the sound
more consistent and powerful. Choose the setting that’s appropriate for your particular
song. Use this if you’re creating music that will be made into an audio CD.
SHARP: The low-frequency and high-frequency ranges will be emphasized.
CLEAR: The high-frequency range will be controlled.
POWER: The mid-frequency range will be emphasized.

Auto Power Off Time

OFF, 5min,
30min

Specifies the time after which the power will automatically turn off if the SD-50 has not
been operated.

Auto Save Mode

OFF, 1min, 3min,
5min, 10min,
15min, 20min,
30min, 60min

Specifies the time after which the SD-50 will automatically enter power-conservation
mode if no operation has been performed. When power-conservation mode is
activated, the SD-50 will be in the following state to conserve power consumption.

Display backlight will turn off

BATTERY indicator will blink

MIDI IN will not operate

Press the [ENTER] button to cancel power-conservation mode.

SD-50_e.book 73 ページ 2010年1月25日 月曜日 午前10時52分

Advertising