Serial communications, 1 rs-232 connection and port configuration, 2 serial command syntax – Runco CINEMAWALL XP-OPAL65 User Manual

Page 69: Examples, Rs-232 connection and port configuration, Serial command syntax, Serial, Pre l iminar y

Advertising
background image

CinemaWall Installation/Operation Manual

55

PRE

L

IMINAR

Y

6.1
RS-232 Connection
and Port Configuration

To interface the CinemaWall with a home theater automation/control system or a PC
running terminal emulation software, connect it to your control system or PC as shown in
Figure 3-5. Use a straight-through cable.

Configure the RS-232 controller or PC serial port as follows:

• 9600 baud

• No parity

• Eight (8) data bits

• One (1) stop bit

• No flow control

6.2
Serial Command
Syntax

Serial commands to the CinemaWall take the following form:

• You can send commands in either hexadecimal or ASCII format.

• ASCII commands are case-sensitive and must be in

UPPERCASE.

• Commands begin with the “Start of Text” (STX) character (02h or

<Ctrl> B in ASCII),

followed by the command data, the colon character (3Ah or

: in ASCII), command

parameter (1 to 8 bytes; refer to Table 6-1) and the “End of Text” (ETX) character (03h
or

<Ctrl> C in ASCII). Not all commands require parameters to be sent with them;

examples of such commands are

PON (power on), POF (power off) and IMS (toggle

input selection).

• You do not need to send a carriage return after the command.

• When sending multiple commands, be sure to wait for a response to the first command

to come from the CinemaWall before sending the next command.

• When you send a valid command, the CinemaWall executes it and echoes the

command (without the parameter) back to the controller.

• If you send an invalid command, the CinemaWall sends

ER401 back to the controller.

Examples

To select the PC input, send the following sequence:

To set the Picture Level (contrast) to its highest possible level (+30), send the following
sequence:

6. Serial Communications

STX

Command (3 bytes)

Parameter (3 bytes)

ETX

Hex

02

49 4D 53

3A

50 43 31

03

ASCII

<Ctrl>

B

I M S

:

P C 1

<Ctrl>

C

STX

Command (3 bytes)

Parameter (6 bytes)

ETX

Hex

02

56 50 43

3A

50 49 43 30 33 30

03

ASCII

<Ctrl>

B

V P C

:

P I C 0 3 0

<Ctrl>

C