Important warning, Powering on the controller – RoboteQ Dual Channel Digital Motor Controller AX500 User Manual

Page 17

Advertising
background image

AX500 Motor Controller User’s Manual

17

Powering On the Controller

This wiring - with the wire loop uncut - assumes that the R/C radio will be powered by the
AX500 controller. Other wiring options are described in “R/C Operation” on page 81 of the
User’s Manual.

Important Warning

Do not connect a battery to the radio when the wire loop is uncut. The RC battery
voltage will flow directly into the controller and cause permanent damage if its volt-
age is higher than 5.5V.

Connecting the optional channel 3 will enable you to turn on and off the accessory output.
See “Connecting Sensors and Actuators to Input/Outputs” on page 47 and “Data Logging
in R/C Mode” on page 91
of the User’s Manual.

Powering On the Controller

Important reminder: There is no On-Off switch on the controller. You must insert a switch
on the controller’s power terminal as described in section“Connecting to the Batteries and
Motors” on page 15.

To power the controller, center the joystick and trims on the R/C transmitter. In Analog
mode, center the command potentiomenter or joystick.Then turn on the switch that you
have placed on the on the VCon wire.

8

9

15

Pin 1

Channel 1

Wire loop bringing power from
controller to RC radio

Channel 2

3:

Channel 1 Command Pulses

4:

Channel 2 Command Pulses

6:

Radio battery (-) Ground

7: Radio

battery

(+)

8:

Channel 3 Command Pulses

Channel 3

FIGURE 4. R/C connector wiring for 3 channels and battery elimination (BEC)

Advertising