HCD-E1 Installation & Operation Manual
Chapter 4 - Control from the Supervisory Port
11/01/00 19:23
HCD-E1 Command Set Description
4-17
A typical display, as seen after all the parameters are selected, is shown
below:
DAY
= 01
MONTH
= 03
YEAR [4 CHARS]
= 1996
WEEK DAY
=FRI
Below HCD-E1 displays the date and time (note that the date has changed),
followed by the HCD-E1 prompt.
DEF AGENT
Purpose
Display and modify the current SNMP agent parameters. Refer to
Appendix A for additional explanations.
To enable SNMP and Telnet management, it is necessary to define all the
parameters.
Syntax
DEF AGENT
Use
1. To define the SNMP agent parameters, type:
DEF AGENT<CR>
You will see the entry line for the first parameter,
TELNET_APATHY_TIME
10 MIN
2. If you do not want to change the current value of the parameter, press
<CR> to confirm it and continue to the next line, otherwise type in the
new value and then press <CR>. HCD-E1 displays the entry line for
the next parameter.
3. Repeat the procedure until all the parameters are defined, and then
press <CR> to end.
A typical display, as seen after all the parameters are selected, is shown
below:
IP ADDRESS IS:
=
192.114.029.233
READ COMMUNITY IS:
=
public
WRITE COMMUNITY IS:
=
private
TRAP COMMUNITY IS:
=
public
After performing the command, HCD-E1 displays the date and time,
followed by the HCD-E1 prompt.