RAD Data comm HCD-E1 User Manual

Page 131

Advertising
background image

HCD-E1 Installation & Operation Manual

Chapter 4 - Control from the Supervisory Port

11/01/00 19:23

HCD-E1 Command Set Description

4-47

Following is a list of fields appearing in the time slot display:

TS

Indicates the main link time slot number 0 through 31

TYPE

Indicates the type of time slot assignment:
NC

time slot not assigned

CH1

time slot is assigned to data channel 1

CH2

time slot is assigned to data channel 2

SL

time slot is assigned to E1 sublink

DEDIC

time slot is assigned for in-band management

After performing the command, HCD-E1 displays the date and the time
followed by the HCD-E1 prompt.

EXIT

Purpose

End the current session and return control to the HCD-E1 front panel.

Syntax
EXIT

Use

•

Type:

EXIT<CR>

HCD-E1 performs the command and displays the date and the time
followed by the HCD-E1 prompt.

F

Purpose

Define the codes used to be sent to the supervision terminal to perform the
following terminal control functions:

•

Clear the screen

•

Move the cursor to the screen home position.

•

Move the cursor to the right by one position.

The codes used by typical terminals are listed in the following table:

Function

Terminal Type

TV920

VT52

VT100

Freedom100

Freedom220

Clear Screen

1B2A0000

N/A

1B5B324A

1B2A0000

1B5B324A

Cursor Home

1E000000

1B480000

1B5B4800

1E000000

1B5B4800

Cursor Right

0C000000

1B430000

1B5B3143

0C000000

1B5B0143

Advertising