HCD-E1 Command Set Description

4-15

CLR LOOP

Purpose

Deactivate the specified user-initiated loopback or test.

Syntax
CLR LOOP [loop type], or CLR LP [loop type]

Use

To deactivate a local (L) loopback on the HDSL lines, type:

CLR LOOP L LINE<CR> or CLR LP L LINE<CR>*

To deactivate a local (L) loopback on the E1 sublink of the local HCD-E1,
type:

CLR LOOP L SL<CR> or CLR LP L SL<CR>

To deactivate the remote (R) loopback on the E1 sublink of the local
HCD-E1, type:

CLR LOOP R SL<CR> or CLR LP R SL<CR>

To deactivate a remote (R) loopback on the E1 sublink of the remote
unit, type:

CLR LOOP R R SL<CR> or CLR LP R R SL<CR>

To deactivate the local (L) loopback on data channel X of local HCD-E1,
type:

CLR LOOP L CH X<CR> or CLR LP L CH X<CR>

To deactivate the remote (R) loopback on data channel X of local
HCD-E1, type:

CLR LOOP R CH X<CR> or CLR LP R CH X<CR>

To deactivate the remote (R) loopback on data channel X of remote
HCD-E1, type:

CLR LOOP R R CH X<CR> or CLR LP R R CH X<CR>

To deactivate the BERT test on data channel X of HCD-E1, type:

CLR LOOP BERT CH X<CR> or CLR LP BERT CH X<CR>

To deactivate the in-band loopback on data channel X of the remote
unit, type:

CLR LOOP INBAND CH X<CR> or CLR LP INBAND CH X<CR>

To deactivate a local loopback on the H-RPT, type:

CLR LOOP L HRPT<CR> or CLR LP L HRPT<CR>*

* These commands are available only from the unit configured as central.

HCD-E1 performs the command and displays the date and time, followed
by the HCD-E1 prompt. The TST LED goes off, if there are no more tests
activated.