Maintenance and repair instructions – Ryobi 790r User Manual

Page 16

Advertising
background image

16

MAINTENANCE AND REPAIR INSTRUCTIONS

Fig. 28

Fig. 29

Fig. 30

Fig. 31

Fig. 32

Fig. 27

NOTE: SplitLine™ can only be used with the inner reel

with the slotted holes. Single line can be used on
either type of inner reel. Use Figure 27 to identify
the inner reel you have.

NOTE: Always use the correct line length when installing

trimming line on the unit. The line may not release
properly if the line is too long.

Single Line Installation

Go To Step 8 for SplitLine™ Installation

6. Take approximately 40 feet (12.2 m) of new trimming

line, loop it into two equal lengths. Insert each end of
the line through one of the two holes in the inner reel
(Fig. 28). Pull the line through the inner reel so that
the loop is as small as possible.

7. Wind the lines in tight even layers, onto the reel

(Fig. 29). Wind the line in the direction indicated on
the inner reel. Place your index finger between the
two lines to stop the lines from overlapping. Do not
overlap the ends of the line. Proceed to step 11.

Spring

SplitLine™ Installation

8. Take approximately 20 feet (6.1 m) of new trimming

line. Insert one end of the line through one of the two
holes in the inner reel (Fig. 30). Pull the line through
the inner reel until only about 4 inches is left out.

9. Insert the end of the line into the open hole in the

inner reel and pull the line tight to make the loop as
small as possible (Fig. 30).

10. Before winding, split the line back about 6 inches.

11. Wind the line in tight even layers in the direction

indicated on the inner reel.

NOTE: Failure to wind the line in the direction indicated will

cause the cutting attachment to operate incorrectly.

Loop

Slotted

Holes

For Use with SplitLine™

or Single Line

For Use with Single

Line ONLY

Loop

Holding Slots

NOTE: The spring must be assembled on the inner reel

before reassembling the cutting attachment.

14. Hold the inner reel in place and install the bump knob

by turning counterclockwise. Tighten securely.

12. Insert the ends of the line into the two holding slots

(Fig. 31).

13. Insert the ends of the line through the eyelets in the

outer spool and place inner reel with spring inside the
outer spool (Fig. 32). Push the inner reel and outer
spool together. While holding the inner reel and outer
spool, grasp the ends and pull firmly to release the
line from the holding slots in the reel.

Advertising