APPLICATION

2.2 Interrupts

2-23

4513/4514 Group User’s Manual

Fig. 2.2.7 Timer 3 constant period interrupt setting example

g0 h

0

b3

b0

➀

Disable Interrupts

Timer 3 interrupt is temporarily disabled.

Interrupt enable flag INTE

Interrupt control register V2

“0”

✕

✕

✕

All interrupts disabled (DI instruction)

Timer 3 interrupt occurrence disabled
(TV2A instruction)

b3

b0

0 1

➁

Stop Timer 3 Operation

Timer 3 and prescaler are temporarily stopped.
Dividing ratio of prescaler is selected.

Timer control register W1

✕

Prescaler stop (TW1A instruction)
Prescaler divided by 16 selected

Timer 3 stop (TW3A instruction)
Prescaler selected for count source

b3

b0

0

1

0

Timer control register W3

✕

✕

➂

Set Timer Value

Timer 3 count time is set. (The formula is shown

❈

A below.)

Timer 3 reload register R3

“52

16

”

Timer count value 82 set (T3AB instruction)

➃

Clear Interrupt Request

Timer 3 interrupt activated condition is cleared.

Timer 3 interrupt request flag T3F “0”

Timer 3 interrupt activated condition cleared
(SNZT3 instruction)

Note when the interrupt request is cleared

When

➃

is executed, considering the skip of the next instruction according to the

interrupt request flag T3F, insert the NOP instruction after the SNZT3 instruction.

b3

b0

0

1

1

➄

Start Timer 3 Operation

Timer 3 and prescaler temporarily stopped are restarted.

Timer control register W3

Timer 3 operation start (TW3A instruction)

Prescaler operation start (TW1A instruction)

✕

b3

b0

1 1

Timer control register W1

✕ ✕

b3

b0

1

➅

Enable Interrupts

The timer 3 interrupt which is temporarily disabled is enabled.

Interrupt control register V2

Interrupt enable flag INTE

“1”

Timer 3 interrupt occurrence enabled
(TV2A instruction)
All interrupts enabled (EI instruction)

✕

✕

✕

Constant period interrupt execution start

❈

A The prescaler dividing ratio and time 3 count value to make the interrupt occur every 1 ms are set as follows.

1 ms

≅

(4.0 MHz)

✕

3

✕

16

✕

(82+1)

–1

System clock Instruction

clock

Prescaler
dividing
ratio

Timer 3
count
value

“

✕

”: it can be “0” or “1.”