APPLICATION

2.3 Timers

2-36

4513/4514 Group User’s Manual

Fig. 2.3.7 Timer start by external input setting example (1)

0

b3

b0

➀

Disable Interrupts

Timer 1 interrupt is temporarily disabled.

Interrupt enable flag INTE

Interrupt control register V1

“0”

✕

✕

All interrupts disabled (DI instruction)

Timer 1 interrupt occurrence disabled
(TV1A instruction)
INT0 interrupt occurrence disabled

0

b3

b0

0 0

➁

Stop Timer Operation

Timer 1 and prescaler are temporarily stopped.
Dividing ratio of prescaler is selected.

Timer control register W1

✕

Timer 1 stop (TW1A instruction)
Prescaler stop
Prescaler divided by 4 selected

0

➂

Set Timer Value

Timer 1 count time is set.

Timer 1 reload register R1 “52

16

”

Timer count value 82 set (T1AB instruction)

b3

b0

1

➃

Set Port

P3

0

/INT0 pin is set to INT0 input.

Port P3

0

output latch

✕ ✕ ✕

INT0 input set (OP3A instruction)

b3

b0

1

➄

Set Valid Waveform

Valid waveform of INT0 pin is selected. Timer 1 control is enabled.

Interrupt control register I1

✕

Rising edge detected (TI1A instruction)

1 0

g0 h

➅

Clear Interrupt Request

Timer 1 interrupt activated condition is cleared.
INT0 interrupt activated condition is cleared.

Timer 1 interrupt request flag T1F

INT0 interrupt request flag EXF0

“0”

Timer 1 interrupt activated condition cleared
(SNZT1 instruction)
INT0 interrupt activated condition cleared
(SNZ0 instruction)

“0”

Note when the interrupt request is cleared

When

➅

is executed, considering the skip of the next instruction according to the

interrupt request flags T1F and EXF0, insert the NOP instruction after the SNZT1
and SNZ0 instructions.

b3

b0

1

➆

Enable Interrupts

The timer 1 interrupt which is temporarily disabled is enabled.

Interrupt control register V1

Interrupt enable flag INTE

“1”

Timer 1 interrupt occurrence enabled
(TV1A instruction)
All interrupts enabled (EI instruction)

✕

✕

✕

Timer start by external input

“

✕

”: it can be “0” or “1.”