2 a-d converter application examples, Application, 5 a-d converter – Renesas 4514 User Manual

Page 154

Advertising
background image

APPLICATION

2.5 A-D converter

2-51

4513/4514 Group User’s Manual

2.5.2 A-D converter application examples

(1)

A-D conversion mode

Outline: Analog input signal from a sensor can be converted into digital values.
Specifications: Analog voltage values from a sensor is converted into digital values by using a 10-

bit successive comparison method. Use the A

IN0

pin for this analog input.

Figure 2.5.2 shows the A-D conversion mode setting example.

Fig. 2.5.2 A-D conversion mode setting example

b3

b0

➀

Disable Interrupts

A-D interrupt is temporarily disabled.

Interrupt enable flag INTE

Interrupt control register V2

“0”

✕

✕

All interrupts disabled (DI instruction)

A-D interrupt occurrence disabled
(TV2A instruction)

0

✕

➁

Set A-D Converter

A-D conversion mode is selected to A-D operation mode.
Analog input pin A

IN0

is selected.

A-D control register Q2

A-D conversion mode selected (TQ2A instruction)

A

IN0

selected (TQ1A instruction)

A-D control register Q1

b3

b0

✕

0

b3

b0

0 0

✕

0

✕ ✕

➂

Clear Interrupt Request

A-D interrupt activated condition is cleared.

A-D conversion completion flag ADF “0”

A-D conversion interrupt activated condition cleared
(SNZAD instruction)

Note when the interrupt request is cleared

When

➂

is executed, considering the skip of the next instruction according to the

flag ADF, insert the NOP instruction after the SNZAD instruction.

When interrupt is

not used

When interrupt is used

➃

Set Interrupt

Interrupts except A-D conversion is
enabled (EI instruction)

➃

Set Interrupt

A-D conversion interrupt temporarily disabled is enabled.

b3

b0

1

✕

✕ ✕

Interrupt control register V2

A-D interrupt occurrence enabled
(TV2A instruction)

Interrupt enable flag INTE “1”

All interrupts enabled
(EI instruction)

➄

Start A-D Conversion

A-D conversion operation is started (ADST instruction).

When interrupt is not used

When interrupt is used

➅

Check A-D Interrupt Request

A-D conversion completion flag is
checked (SNZAD instruciton)

➅

A-D Conversion Interrupt Occur

➆

Execute A-D Conversion

High-order 8 bits of register AD

→

register A and register B (TABAD instruction)

Low-order 2 bits of register AD

→

high-order 2 bits of register A (TALA instruction)

“0” is set to low-order 2 bits of register A

“

✕

”: it can be “0” or “1.”

When A-D conversion is executed by the same channel,

➄

to

➆

is repeated.

When A-D conversion is executed by the another channel,

➀

to

➆

is repeated.