Installation – Regency Ultimate U39-LP1 User Manual

Page 14

Advertising
background image

14

Regency

®

U39 ULTIMATE Direct Vent Freestanding Gas Stove

Horizontal Venting with Two (2) 90

o

Elbows

Option V

H + H1

A)

3' Min. 2' Max.

B)

5' Min. 3' Max.

C)

8' Min. 4' Max.

With these options, maximum total
pipe length is 30 feet with minimum
of 8 feet total vertical and maximum
4 feet total horizontal.
Please note minimum 1 foot
between 90

o

elbows is required.

INSTALLATION

One 90

o

elbow = Two 45

o

elbows.

Vertical Venting with Two (2) 90

o

Elbows

Option V

H

V1

V + V1

A)

1' Min. 1' Max. 1' Min. 2' Min.

B)

1' Min. 2' Max. 2' Min. 3' Min.

C)

2' Min. 3' Max. 2' Min. 4' Min.

D)

2' Min. 4' Max. 2' Min. 4' Min.

With these options, max. total pipe length is 30
feet with min. of 4 feet total vertical and max. 4 feet
total horizontal.
Please note min. 1 foot between 90

o

elbows is

required.

One 90

o

elbow = Two 45

o

elbows.

Vent restrictor position A (fully
open), Refer to the "Venting Ar-
rangement" section.

Vent restrictor position A (fully open). Refer to
the "Venting Arrangement" section.

Lengths do not include elbow
indicated

Lengths do not include elbow indicated

Advertising
This manual is related to the following products: