16) Pull off the pilot cap to expose the pilot

orifi ce.

17) Unscrew the pilot orifi ce with the allen

key and replace with the LPG pilot
orifi ce in the kit.

19) Reinstall new burner orifi ce LPG

stamped #50 and tighten.

20) Reverse steps 3) to 2).

21) Attach the label "This unit has been

converted to LPG" near or on top of the
Serial # decal.

22) Replace yellow "NG" label with red

"LPG" label.

15) Re-assemble the black protection cap

(Fig. 6).

WARNING!

Also check that the pilot

and main burner injectors are

appropriate for the gas type.

Installation of the DC Sparker:

1) Remove the back pedestal cover by

unscrewing the 4 screws.

2) Remove the front control panel by

unscrewing the 6 screws.

4) Plug up the Piezo Ignitor mounting hole

with the plastic plug.

Fig. 6

Burner Orifi ce

18) Remove burner orifi ce with a 1/2"

wrench while using a 9/16" wrench to
hold onto the elbow behind the orifi ce,
then discard the orifi ce.

WARNING!

Do not over tighten the screw.

Recommended to grip the

wrench by the short side.

14) Verify that if the conversion is from

NG to LPG, the screw must be re-
assembled with the red o-ring visible
(Fig. 5).

LPG Configuration

Red o-ring visible

Fig.5

3) Unplug the Piezo Ignitor wire and

remove Piezo Ignitor from the control
panel.

5) Connect the DC spark generator wires

to the SIT Valve with the screw, which is
provided in the kit.

ONLY REQUIRED FOR THE U38