Roberts Gorden VANTAGE HE HE-125 User Manual

Page 13

Advertising
background image

SECTION 3: C

LEARANCES

TO

C

OMBUSTIBLES

7

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.

2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream
from where the burner and burner tube connect.

FIGURE 6: 45

°

TILT REFLECTOR

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

HE-40

8

8

51

46

21

21

130

117

HE-60

8

8

60

54

21

21

153

138

HE-80

8

8

66

60

21

21

168

153

HE-100

10

8

74

64

26

21

188

163

HE-125

10

8

78

69

26

21

199

176

HE-150

12

8

84

74

31

21

214

188

HE-175

12

8

85

79

31

21

216

201

FIGURE 7: U-TUBE, STANDARD REFLECTOR

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

HE-40

- UNAPPROVED -

- UNAPPROVED -

HE-60

6

35

63

30

16

89

161

77

HE-80

6

38

69

37

16

97

176

94

HE-100

6

40

76

39

16

102

194

100

HE-125

6

46

79

43

16

117

201

110

HE-150

6

50

84

47

16

127

214

120

HE-175

8

54

87

51

21

138

221

130

FIGURE 8: U-TUBE, 45

°

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

HE-40

- UNAPPROVED -

- UNAPPROVED -

HE-60

8

8

60

42

21

21

153

107

HE-80

8

8

66

46

21

21

168

117

HE-100

8

8

74

52

21

21

188

133

HE-125

8

8

78

61

21

21

199

155

HE-150

8

8

84

66

21

21

214

168

HE-175

8

8

85

70

21

21

216

178

B

C

D

A

Advertising
This manual is related to the following products: