Warning – Roberts Gorden CoRayVac CRV-B-6 User Manual

Page 39

Advertising
background image

SECTION 9: P

UMP

I

NSTALLATION

AND

V

ENTING

33

SECTION 9: PUMP INSTALLATION AND
VENTING

9.1 Pump Installation

For complete pump installation, please refer to the EP-100, EP-200 or EP-300 Series Installation,
Operation and Service Manuals.

FIGURE 16: EP-200 Condensate Valve Assembly

WARNING

Carbon Monoxide Hazard

Heaters installed unvented must be interlocked

with sufficient building exhaust.

Heaters must be installed according to the

installation manual.

Failure to follow these instructions can result

in death or injury.

WARNING

Cut/Pinch Hazard

Wear protective gear during installation,
operation and service.

Edges are sharp.

Failure to follow these instructions can result
in injury.

Wall

1" NPT threaded hole.

Use 1" x ¾" reducer.

(not supplied)

Must be connected
to a drain system
in accordance with
local codes.

flow

Condensate

Valve

Assembly

3/4" female

3/4" female

36" (0.9 m)

Minimum

vertical drop

between pump

and condensate

valve assembly.

Copper or

galvanized pipe

between pump

and condensate

valve.

Description

Part Number

Condensate Valve Assembly

01327001