RoyalTek REV-2000 User Manual

Page 39

Advertising
background image

RoyalTek GPS Receiver REB-2000/REB-12R REV-2000 Operational Manual

22

Table 24 DOP Mask Control

Binary(Hex)

Name

Bytes

Scale Example

Units

Description

Message ID

1

88

ASCII 137

DOP Selection

1

00

See Table 25

GDOP Value

1

08

Range 1 to 50

PDOP Value

1

08

Range 1 to 50

HDOP Value

1

08

Range 1 to 50

Payload Length: 5 bytes

Table 25 DOP Selection

Byte Value

Description

0 Auto

PDOP/HDOP

1 PDOP
2 HDOP
3 GDOP
4

Do Not Use

DGPS Control – Message I.D.138

Table 26 contains the input values for the

following example:

Set DGPS to exclusive with a time out of

30 seconds.

Example:

A0A20003 – Start Sequence and Payload

Length

8A011E – Payload

00A9B0B3 – Message Checksum and

End Sequence

Table 26 DGPS Control

Binary(Hex)

Name

Bytes

Scale Example

Units

Description

Message ID

1

8A

ASCII 138

DGPS Selection

1

01

See Table 27

DGPS Time Out

1

1E

Seconds

Range 1 to 120

Payload Length:3 bytes

Table 27 DGPS Selection

Byte Value

Description

0 Auto

1 Exclusive
2 Never
3

Mixed (not recommended)

Elevation Mask – Message I.D.139

Table 28 contains the input values for the

following example:

Set Navigation Mask to 15.5 degrees

(Tracking Mask is defaulted to 5 degrees).

Example:

A0A20005 – Start Sequence and Payload

Length

8B0032009B – Payload

0269B0B3 – Message Checksum and End

Sequence

Advertising