RoyalTek REV-2000 User Manual

Page 49

Advertising
background image

RoyalTek GPS Receiver REB-2000/REB-12R REV-2000 Operational Manual

32

data and carrier data for each measurement

epoch.

1. Computation of initial Receiver

Time(RT) in seconds. Note-Where the

initial arbitrary value chosen at start

up to make the PR reasonable

(i.e.,set equal to TT+70ms) and then

incriminated by one second for each

measurement epoch.

2. Computation of Transmit Time (TT) in

seconds.

3. Calculate Pseudo-range at a common

receiver time of the first channel of

the measurement data set. Note-All

channel measurements are NOT

taken at the same time. Therefore, all

ranges must be extrapolated to a

common measurement epoch. For

simplicity, the first channel of each

measurement set is used as the

reference to which all other

measurements are extrapolated.

4. Extrapolate the pseudo-range based

on the correlation interval to improve

precision.

5. Compute the delta range.

If the accumulation time of the Dalta Carrier

Phase is 1000 ms then the measurement is

valid and can be added to the previous Delta

Carrier Phase to get Accumulated Carrier

Phase data. If the accumulation time of the

Delta Carrier Phase is not equal to 1000 ms

then the measurement is not valid and the

accumulation time must be restarted to get

Accumulated Carrier Phase data.

Response :Software Version
String – Message I.D.6

Output Rate:Response to polling message

Example:

A0A20015 – Start Sequence and Payload

Length

0606312E322E30444B495431313920534

D0000000000-Payload

0382B0B3 – Message Checksum and End

Sequence

Table 47 Software Tracker Data Out

Binary(Hex) ASCII(Decimal)

Name

Bytes

Scale Example

Units

Scale Example

Message

ID 1 06

6

Character 20 1

2

Payload Length: 21 bytes

Note – Convert to symbol to assemble message (i.e., 0x4E is ’N’). These are low priority task and

are not necessarily output at constant intervals.

Response :Clock Status Data – Message I.D.7

Output Rate:1Hz or response to polling message

Example:

A0A20014 – Start Sequence and Payload Length

0703BD021549240822317923DAEF – Payload

Advertising