ASMi-31 Installation and Operation Manual

Chapter 2. Installation and Setup

16-05-01 13:37

Installation and Setup

2-5

Table 2-1 ASMi-31 Internal Jumpers and Switches (Cont.)

Item Jumper

Description

Values

Default Setting

3

LLB, JP15

Controls the local loopback

activation from the DTE

DIS

– The LLB activation from

the DTE is disabled
EN

– The LLB activation from

the DTE is enabled

DIS

4

CLOCK

Controls the ASMi-31 timing
reference

LBT

– Loopback timing, clock is

recovered from the data at the

line side
INT

– Internal clock

EXT

– External clock

LBT

5

SW7

Selects the data rate

1

– 1.2 kbps, sync/async

2

– 2.4 kbps, sync/async

3

– 4.8 kbps, sync/async

4

– 9.6 kbps, sync/async

5

– 19.2 kbps, sync/async

6

– 38.4 kbps, sync/async

7

– 48 kbps, sync

9

– 64 kbps, sync

A

– 128 kbps, sync

E

– 16 kbps, sync

F

– 32 kbps, sync

9 – 64 kbps

5

SW6

DIP switch, which consists of eight section

Section 1

Controls the ASMi-31 operation

mode – synchronous or

asynchronous

ON

– Async operation

OFF

– Sync operation

Sync

Section 2

Defines the number of data bits
to be used

ON

– 8 bits

OFF

– 7 bits

8 bits

Section 3

Controls the use of parity

ON

– Parity enabled

OFF

– Parity disabled

P.EN

Section 4

Defines the parity type

ON

– Even parity

OFF

– Odd parity

Even

Section 5

Defines the number of stop bits ON – One stop bit

OFF

– Two stop bits

1STB

Section 6

Controls the RTS to DCD
transfer

ON

– DCD, the DCD signal

turns on when the two units
reach synchronization
OFF

– CNT, the DCD signal of

the local unit follows the RTS

signal of the remote unit

DCD

Note: The DCD signal is OFF when a digital loopback is active (receiving RLB command) or when there is no

synchronization between the units).