Chapter 2. Installation and Setup

ASMi-31

Installation and Operation Manual

2-6

Installation and Setup

16-05-01 13:37

Table 2-1 ASMi-31 Internal Jumpers and Switches (Cont.)

Item Jumper

Description

Values

Default Setting

Section 7

Controls the DTR to DSR
transfer

ON

– Indicates only that the

local unit is powered up. It

does not indicate the status of

the communication channel or

operational status of the remote

site
OFF

– Indicates that the DSR of

the local unit follows the DTR

signal of the remote unit

DSR

Section 8

Controls the ASMi-31

operational status – slave or

master

ON

– Slave

OFF

– Master

Slave

Closing the ASMi-31 Case

After completing the internal settings, close the unit case.

To close the ASMi-31 case:

1. Replace the upper half of the unit and press firmly until the plastic tabs

fit into the tab housing.

2. Insert the original cover screws in their positions and tighten carefully.

Do not use excessive torque.

Connecting the
Interfaces

Figure 2-2 illustrates the rear panel of the ASMi-31 modem.

~230V 0.1A T 250V

DTE

LINE
GND

2 4 5

Figure 2-2 ASMi-31 Rear Panel

Connecting the Line
The ASMi-31 line connector is a terminal block/RJ-45 connector. Connect
the transmission line (twisted pair) to the two clips marked LINE and the
cable shield to the clip marked GND (optional). High rate data
communication twisted pair cable is highly recommended in order to
prevent crosstalk.
Before connecting the cables, make sure that the equipment is earthed by
its power cable.

Caution

Insert the GND lead first.