Gas pressure setting – Rinnai 16e User Manual

Page 27

Advertising
background image

27

GAS PRESSURE SETTING


11.Remove rubber access plug and adjust the

regulator screw on the modulating valve (fig.
4) as required to the pressure below.







12.Lock the regulating screw on the modulating

valve.


13.Set the appliance to 'Forced High' combustion

by setting both no. 3 and no. 4 dipswitches of
the bottom set of switches (SW1) to 'ON'.
(fig.5) Ensure maximum water flow.


14.Check the burner test point pressure.

15.Adjust the high pressure potentiometer on the

Printed Circuit Board between SW1 and SW2
to the pressure shown below. The potentiome-
ter is very sensitive, turn no more than a few
degrees at a time; then let the pressure settle
down before turning it more.







16.IMPORTANT: Set dip switch no. 3 and no. 4

on the bottom set of switches (SW1) to 'OFF'
to return the appliance to 'Normal' combustion.
(fig. 6)


17.Close hot water tap.

18.Turn OFF the gas supply and 230V power

supply.


19.Remove pressure gauge, and replace sealing

screw.


20.Turn 'ON' the gas supply and 230V power

supply.


21.Operate unit and check for gas leaks at test

point.


22. Replace the front cover of the appliance.

N.G

1.8 mbar

Propane 1.8 mbar

N.G

8.8 mbar

Propane

8.1 mbar

CAUTION

LEGEND:

Black Section indicates
position of dip switch.

OFF ON

OFF ON

OFF ON

Advertising