CC-SG comes with a few diagnostic utilities which may be extremely 
helpful for you or Raritan Technical Support to analyse and debug the 
cause of CC-SG problems. 
In This Chapter
Memory Diagnostic................................................................................338 
Debug Mode ..........................................................................................339 
CC-SG Disk Monitoring .........................................................................340 
Memory Diagnostic
CC-SG is implemented with the Memtest86+ diagnostic program, which 
can be invoked from the GRUB menu . When any memory problems 
occur, you can perform the Memtest86+ diagnostic test for 
troubleshooting. 
1: Perform the Memtest86+ diagnostic program:
1.
Reboot CC-SG
(see "Reboot CC-SG with Diagnostic Console" on
page 284).
2. When it shows the messages below, press any character within 5
seconds to enter the GRUB menu, such as the Esc or arrow key.
Press any key to enter the menu
Booting CentOS (x.x.x) in x seconds....
3. Highlight the "Memtest86+ vX.X" option (where vX.X is the current
version) using the up or down arrow keys, and press Enter.
4. CC-SG loads and performs the Memtest86+ diagnostic program. Let
the program run at least one complete pass, that is, when the Pass 
column shows "1". For extensive test, leave the program running for 
multiple hours or even overnight. 
5. Verify these items to determine whether there are memory errors.
 Memory: The amount of total memory should match your CC-SG
type: 512M for G1, 2048M for V1, and 4096M for E1.
 Errors: The column should show "0"
 Error display area: The area is the bottom area right below the
WallTime row. The program should display nothing in this area to 
indicate there are no errors. 
If any of the above items indicates that there are memory errors, you 
can: 