Section 16: removal and replacement parts, 1 gas valve, 36, step 16.1 – Roberts Gorden Compact Tubular Unit Heaters CTCU 27 User Manual

Page 42: 1 fo, Warning, Danger

Advertising
background image

COMBAT

®

CTCU U

NIT

H

EATERS

I

NSTALLATION

O

PERATION

AND

S

ERVICE

M

ANUAL

36 of 42

SECTION 16: REMOVAL AND REPLACEMENT PARTS

See warnings and notes

on Page 27, Section 13

before removing or replacing parts.

Burner Components
All serviceable burner parts are accessed by the
door on the right side of the heater. Use a
screwdriver to turn the latch 90°.

See Page 8,

Section 5.

16.1 Gas Valve

Remove the gas supply pipe at the heater inlet.

16.1.1 Models 7 - 32

16.1.2 All Models

Replace in reverse order. Verify that the gas flow
direction of the valve is correct. Use a minimum
amount of gas seal on the thread joint. Re-use the
"O" ring seal in the outlet flange where fitted. Check
that all the joints are leak free. Reset gas valve.

See

Page 23, Section 11.4.2.

IT IS IMPORTANT THAT ONLY THE CORRECT
GAS VALVES SPECIFIED FOR EACH MODEL

TYPE ARE USED WHEN REPLACING THESE
CONTROLS.

Carbon Monoxide Hazard

WARNING

Use only genuine ROBERTS GORDON

®

replacement parts per this installation, operation and

service manual.

Failure to follow these instructions can result in death, electric shock, injury or property damage.

Explosion Hazard

DANGER

Electrical Shock Hazard

Fire Hazard

Description

Part Number

Gas Valve 90033102
Ignition Control

90434021