Olympus CAMERA HOUSING FL-50 User Manual

Page 6

Advertising
background image

8/6/2006

6

ring can be obtained from 10 BAR. If the O-ring is contaminated or suspected of being

contaminated, clean it with a cotton cloth that is free of all chemicals or contamination.
After cleaning inspect the O-ring again.

Once the O-ring has been inspected and verified fit for use, apply a

SMALL

amount of

silicone grease to the O-ring. The silicone grease must be evenly distributed round the

O-ring

Replace the O-ring into the groove; run a finger round the O-ring, to make sure it is

snugly seated in the groove.

(Fig. 4) Stretch the O-ring

4.7 Mounting the flashlight in the housing:

Set the flashlight in normal position. Slide the flashlight all the way into the hot shoe of

the housing until it is stop (Fig. 5), Turn the lock ring follow the direction “LOCK”. Take care

not to excessively tighten the screw (Fig. 6). Note: If you find that control levers do not
locate properly with the buttons, please check again that the flashlight is properly seated to
the limit of the guide rail.

(Fig. 5)

(Fig. 6)


Replace the lid, remember to ensure the pressure release plug is pulled all the way out

while closing, otherwise the air cannot escape. Squeeze the lid closed all the way, you will
hear the hiss of air being expelled.

Advertising