System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Start Code and End Code

Number of Received Bytes

Peripheral Service Time Settings (CX-Programmer: Timer/Peripheral Tab Page)

Fixed Service Time Enable Setting (Set Time to All Events)

Peripheral Service Time

Address

Settings

Function

Related flags and

words

When setting is

read

Word

Bits

+364

00 to 07 00 to FF hex

Default: 00 hex

The frame format
for no-protocol
communications
data (messages)
can be specified.

Specifies the end
code. This setting
is valid when bits
08 to 09 of +365
are set to 01.

A414.15 (RS-422A Port
Settings Changing Flag)

At next cycle (Also
can be changed
with STUP (237).)

08 to 15 00 to FF hex

Default: 00 hex

Specifies the start
code. This setting
is valid when bit 12
of +365 is set to 1.

+365

12

0: Don’t add start code
1: Add start code
Default: 0

Specifies whether
the frame format
for no-protocol
communications is
specified.

Specifies whether
to add a start code.

08 and
09

00: Don’t add end code and
use number of received bytes
setting
01: Add end code
11: Add CR+LF
Default: 00

Specifies whether
to add an end
code.

Address

Settings

Function

Related flags and

words

When setting is

read

Word

Bits

+365

00 to 07 00 hex: 256 bytes

01 to FF hex: 1 to 255
Default: 00 hex

Specifies the data length to send and
receive for no-protocol communica-
tions. The start code and end code are
not included in the data length.
This setting is valid only when bits 08
and 09 of +365 are set to 00.
The default setting for each TXD(236)/
RXD(235) instruction is 256 bytes. This
setting can be set to 01 to FF to set 255
bytes or less.

A414.15 (RS-422A Port
Settings Changing Flag)

At next cycle (Also
can be changed
with STUP (237).)

Address

Settings

Function

Related flags and

words

When setting is

read

Word

Bits

+218

15

0: Default (6.25% of cycle
time)
1: Custom
Default: 0

Sets the default service time or enables
setting of a custom service time.

---

At start of opera-
tion (cannot be
changed during
operation)

Address

Settings

Function

Related flags and

words

When setting is

read

Word

Bits

+218

00 to 07 00 to FF hex:

0.0 to 25.5 ms
(unit: 0.1 ms)
Default: 00 hex

Sets the time to allocate to peripheral
servicing. Bit 15 of +218 must be set to
1 to enable this setting.

---

At start of opera-
tion (cannot be
changed during
operation)