357 auxiliary area allocations appendix d – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual
Page 380

357
Auxiliary Area Allocations
Appendix D
A612
00 to 15 High-
speed
counter 1
monitor
data
Range Comparison Execution
Results Flags
Contains the CTBL(882) execution results for range comparison.
Bits 00 to 15 correspond to ranges 1 to 16.
OFF: No match
ON: Match
A613
00 to 15
Output Bit Pattern
Contains the output bit pattern when a match is found for
CTBL(882) execution results for range comparison
Note If more than one match is found, an OR of the output bit
patterns with matches will be stored here.
A614
00 to 15 High-
speed
counter 2
monitor
data
Range Comparison Results
Same as for high-speed counter 1 monitor data.
A615
00 to 15
Output Bit Pattern
A620 to
A621
00 to 15 Pulse Output 1 PV
Note This item applies when the operation
mode is relative pulse output, absolute pulse
output in linear mode, absolute pulse output in
circular mode, or electronic cam mode.
Contains the pulse output PV as an 8-digit hexadecimal number.
Relative mode: 00000000 to FFFFFFFF hex
Absolute linear mode: 80000000 to 7FFFFFFF hex
Absolute circular mode: 00000000 to circular maximum count
One-shot Pulse Output 1 ON Time
Note This item applies when the operation
mode is one-shot output mode.
Contains the time that the one-shot pulse output has been ON as
an 8-digit hexadecimal number.
0000 0000 to 0000 270F (unit: set by STIM(980))
Pulse Time Measurement 1
Note This item applies when the operation
mode is time measurement mode using a pulse
counter.
Contains the time measured by the pulse counter as an 8-digit
hexadecimal number.
0000 0000 to FFFF FFFF hex (unit: set by STIM(980))
A622 to
A623
00 to 15 Pulse Output 2 PV
Same as for Pulse Output 1 PV.
One-shot Pulse Output 2 ON Time
Same as for One-shot Pulse Output 1 ON time.
Pulse Time Measurement 2
Same as for Pulse Time Measurement 1.
A624
00
Pulse
Output 1
Status
Pulse Output Completed Flag
OFF: Pulse output not completed (OFF during pulse output).
ON: Pulse output completed (ON when pulse distribution has
been completed).
01
Pulse Output Set Flag
OFF: Pulse output amount not set by PULS(886).
ON: Pulse output amount set by PULS(886).
02
Target Frequency Not Reached Flag
OFF: Target speed has been reached during pulse output for
PLS2(887).
ON: Decelerated before reaching the target speed during pulse
output for PLS2(887).
03
Target Comparison Flag
OFF: Comparison stopped.
ON: Comparison in progress.
04
Independent Pulse Output Flag
OFF: Pulses not being output or being output continuously.
ON: Pulses being output.
05
PLS2 Positioning Flag
OFF: Not positioning.
ON: Positioning in progress.
06
Accelerating/Decelerating Flag
OFF: No output or constant-speed output.
ON: Acceleration or deceleration in progress for ACC(888) or
PLS2(887).
07
Pulse Output Flag
OFF: Pulse output stopped.
ON: Pulse output in progress.
A625
00
Pulse
Output 2
Status
Pulse Output Completed Flag
Same as for Pulse Output 1 Status.
01
Pulse Output Set Flag
02
Target Frequency Not Reached Flag
03
Target Comparison Flag
04
Independent Pulse Output Flag
05
PLS2 Positioning Flag
06
Accelerating/Decelerating Flag
07
Pulse Output Flag
Address
Bits
Name
Function